Noninvasive assessment of steatosis and viability of cold-stored human liver grafts by MRI

Liam A.J. Young*, Carlo D.L. Ceresa, Ferenc E. Mózes, Jane Ellis, Ladislav Valkovič, Richard Colling, Constantin C. Coussios, Peter J. Friend, Christopher T. Rodgers

*Corresponding author for this work

Research output: Contribution to journalArticlepeer-review

Abstract

Purpose: A shortage of suitable donor livers is driving increased use of higher risk livers for transplantation. However, current biomarkers are not sensitive and specific enough to predict posttransplant liver function. This is limiting the expansion of the donor pool. Therefore, better noninvasive tests are required to determine which livers will function following implantation and hence can be safely transplanted. This study assesses the temperature sensitivity of proton density fat fraction and relaxometry parameters and examines their potential for assessment of liver function ex vivo. Methods: Six ex vivo human livers were scanned during static cold storage following normothermic machine perfusion. Proton density fat fraction, T1, T2, and (Formula presented.) were measured repeatedly during cooling on ice. Temperature corrections were derived from these measurements for the parameters that showed significant variation with temperature. Results: Strong linear temperature sensitivities were observed for proton density fat fraction (R2 = 0.61, P <.001) and T1 (R2 = 0.78, P <.001). Temperature correction according to a linear model reduced the coefficient of repeatability in these measurements by 41% and 36%, respectively. No temperature dependence was observed in T2 or (Formula presented.) measurements. Comparing livers deemed functional and nonfunctional during normothermic machine perfusion by hemodynamic and biochemical criteria, T1 differed significantly: 516 ± 50 ms for functional versus 679 ± 60 ms for nonfunctional, P =.02. Conclusion: Temperature correction is essential for robust measurement of proton density fat fraction and T1 in cold-stored human livers. These parameters may provide a noninvasive measure of viability for transplantation.

Original languageEnglish
Pages (from-to)3246-3258
Number of pages13
JournalMagnetic Resonance in Medicine
Volume86
Issue number6
DOIs
Publication statusPublished - Dec 2021
Externally publishedYes

ASJC Scopus subject areas

  • Radiology, Nuclear Medicine and Imaging

Keywords

  • liver transplantation
  • MOLLI T
  • normothermic machine perfusion
  • proton density fat fraction
  • static cold storage
  • temperature sensitivity

Fingerprint

Dive into the research topics of 'Noninvasive assessment of steatosis and viability of cold-stored human liver grafts by MRI'. Together they form a unique fingerprint.

Cite this