TY - JOUR
T1 - Goal-Directed Haemodynamic Therapy Improves Patient Outcomes in Kidney Transplantation
AU - Fabes, J
AU - Al, Midani A
AU - Sarna, AS
AU - Hadi, DH
AU - Naji, SA
AU - Banga, NR
AU - Jones, GL
AU - Berry, PD
AU - Wittenberg, MD
PY - 2023/6
Y1 - 2023/6
N2 - Introduction: Kidney transplant graft function depends on optimised haemodynamics. However, high fluid volumes risk hypervolaemic complications. The Edwards Lifesciences ClearSight™ device permits fluid titration through markers of preload and beat-to-beat blood pressure monitoring. We evaluated the implementation of a novel goal-directed haemodynamic therapy protocol to determine whether patient outcomes had improved. Design: A retrospective evaluation of standard care versus goal-directed haemodynamic therapy in adults undergoing kidney transplantation was performed in a single centre between April 2016 and October 2019. Twenty-eight standard-of-care patients received intraoperative fixed-rate infusion and 28 patients received goal-directed haemodynamic therapy. The primary outcome was volume of fluid administered intraoperatively. Secondary outcomes included blood product and vasoactive drug exposure, graft and recipient outcomes. Results: Intraoperative fluid administered was significantly reduced in the goal-directed haemodynamic therapy cohort (4325 vs 2751 ml, P < .001). Exposure to vasopressor (67.9% vs 42.9%, P = .060) and blood products (17.9% vs 3.6%, P = .101) was unchanged. Immediate graft function (82.1% vs 75.0%, P = .515), dialysis requirement (14.3% vs 21.4%, P = .729) and creatinine changes post-operatively were unchanged. In the goal-directed haemodynamic therapy cohort, 1 patient had pulmonary oedema (3.6%) versus 21.4% in the standard cohort. Patients in the goal-directed haemodynamic therapy group were more likely to mobilise within 48 hours of surgery (number needed to treat = 3.5, P = .012). Conclusions: Protocolised goal-directed haemodynamic therapy in kidney transplantation was safe and may improve patient, graft, and surgical outcomes. Clinical trials assessing goal-directed approaches are needed.
AB - Introduction: Kidney transplant graft function depends on optimised haemodynamics. However, high fluid volumes risk hypervolaemic complications. The Edwards Lifesciences ClearSight™ device permits fluid titration through markers of preload and beat-to-beat blood pressure monitoring. We evaluated the implementation of a novel goal-directed haemodynamic therapy protocol to determine whether patient outcomes had improved. Design: A retrospective evaluation of standard care versus goal-directed haemodynamic therapy in adults undergoing kidney transplantation was performed in a single centre between April 2016 and October 2019. Twenty-eight standard-of-care patients received intraoperative fixed-rate infusion and 28 patients received goal-directed haemodynamic therapy. The primary outcome was volume of fluid administered intraoperatively. Secondary outcomes included blood product and vasoactive drug exposure, graft and recipient outcomes. Results: Intraoperative fluid administered was significantly reduced in the goal-directed haemodynamic therapy cohort (4325 vs 2751 ml, P < .001). Exposure to vasopressor (67.9% vs 42.9%, P = .060) and blood products (17.9% vs 3.6%, P = .101) was unchanged. Immediate graft function (82.1% vs 75.0%, P = .515), dialysis requirement (14.3% vs 21.4%, P = .729) and creatinine changes post-operatively were unchanged. In the goal-directed haemodynamic therapy cohort, 1 patient had pulmonary oedema (3.6%) versus 21.4% in the standard cohort. Patients in the goal-directed haemodynamic therapy group were more likely to mobilise within 48 hours of surgery (number needed to treat = 3.5, P = .012). Conclusions: Protocolised goal-directed haemodynamic therapy in kidney transplantation was safe and may improve patient, graft, and surgical outcomes. Clinical trials assessing goal-directed approaches are needed.
U2 - 10.1177/15269248231164165
DO - 10.1177/15269248231164165
M3 - Article
SN - 1526-9248
VL - 33
SP - 150
EP - 155
JO - Progress in Transplantation
JF - Progress in Transplantation
IS - 2
ER -