TY - JOUR
T1 - Drugless and radiographer led: the start of a new era for CT coronary angiography
AU - Morgan-Hughes, Gareth
AU - Mcnally, Rebecca
AU - Gibbs, Christopher Gibbs
AU - Iacovides, Stelios
AU - Kirat-Rai, Prabesh
AU - Thiriphoo, Nang
AU - Powell, Alison
AU - Stuckey, Colin
AU - Thorpe, Ross
AU - Mayo, Louisa
AU - Roobottom, Carl
PY - 2023/6
Y1 - 2023/6
N2 - Objective. Since inception CT coronary angiography (CTCA) has required facilitating beta blockers (BB). However, CT technology has improved rapidly as has radiographer and reporter expertise. Using these factors, we instituted a radiographer led cardiac CT service (RLCCTS), without routine BB, which we studied for quality control (QC). Methods. RLCCTS started October 2021 using a wide detector array CT system, with 20 min slots. QC study was registered with the clinical audit team, University Hospitals Plymouth, CA_2020-21-118. Uniform reporting was agreed including indication, BB administration, demographics, dose length product (DLP) and the coronary artery disease—reporting and data system (CAD-RADS) score. Uncertain CAD-RADS meant a non-diagnostic scan (NDS). Six months of data were collected; stable chest pain (SCP) patients, who have national CTCA QC comparators, were analysed using descriptive statistics. Results. Of 1475 patients, 447 were not SCP patients—known CAD (157); valves (286); removed (4, data incomplete) leaving 1028 SCP patients CTCA for analysis. Demographics—mean age 63 years, body mass index 29, 50.4% women. BB therapy—four patients (two recalls). Overall, 36/1024 or 3.5% were NDS; median DLP 173mGy×cm; mean heart rate (HR) 70 bpm, 99/1024 or 9.7% HR >90 bpm (45% not sinus rhythm). Conclusions. Quality for RLCCTS was judged by NDS rate and DLP. National QC comparators suggest 4% NDS rate; median DLP for SCPP CTCA 209 mGy×cm. RLCCTS compares favourably. With modern cardiac CT, experienced radiographers and reporters, ‘drugless’ RLCCTS can deliver 20 min slot CTCA with satisfactory QC indicators.
AB - Objective. Since inception CT coronary angiography (CTCA) has required facilitating beta blockers (BB). However, CT technology has improved rapidly as has radiographer and reporter expertise. Using these factors, we instituted a radiographer led cardiac CT service (RLCCTS), without routine BB, which we studied for quality control (QC). Methods. RLCCTS started October 2021 using a wide detector array CT system, with 20 min slots. QC study was registered with the clinical audit team, University Hospitals Plymouth, CA_2020-21-118. Uniform reporting was agreed including indication, BB administration, demographics, dose length product (DLP) and the coronary artery disease—reporting and data system (CAD-RADS) score. Uncertain CAD-RADS meant a non-diagnostic scan (NDS). Six months of data were collected; stable chest pain (SCP) patients, who have national CTCA QC comparators, were analysed using descriptive statistics. Results. Of 1475 patients, 447 were not SCP patients—known CAD (157); valves (286); removed (4, data incomplete) leaving 1028 SCP patients CTCA for analysis. Demographics—mean age 63 years, body mass index 29, 50.4% women. BB therapy—four patients (two recalls). Overall, 36/1024 or 3.5% were NDS; median DLP 173mGy×cm; mean heart rate (HR) 70 bpm, 99/1024 or 9.7% HR >90 bpm (45% not sinus rhythm). Conclusions. Quality for RLCCTS was judged by NDS rate and DLP. National QC comparators suggest 4% NDS rate; median DLP for SCPP CTCA 209 mGy×cm. RLCCTS compares favourably. With modern cardiac CT, experienced radiographers and reporters, ‘drugless’ RLCCTS can deliver 20 min slot CTCA with satisfactory QC indicators.
U2 - 10.1136/openhrt-2023-002263
DO - 10.1136/openhrt-2023-002263
M3 - Article
SN - 2053-3624
VL - 10
JO - Open Heart
JF - Open Heart
IS - 1
ER -