Abstract
A physical comparison of a single isolated Spar Buoy
type oscillating water column with two mooring types was carried
out in Plymouth University’s Coast Laboratory. A simple
catenary chain solution was compared to a hybrid line with floats
and sinkers. The effect on performance via a decoupled motion
analysis, as well as mooring tension was investigated. Results
indicated a performance improvement can be made through the
use of hybrid moorings.
Original language | English |
---|---|
Number of pages | 0 |
Journal | Default journal |
Volume | 0 |
Issue number | 0 |
Publication status | Published - 30 Aug 2017 |
Event | 12th European Wave and Tidal Energy Conference - Cork, Ireland Duration: 28 Aug 2017 → 31 Aug 2017 |